Chesapeake (VA) Auto Parts Store Roof Collapse Double LODD 1996-2016

Entry Img

Two firefighters were killed in Chesapeake, Virginia when they became trapped by a rapidly spreading fire.

Predictability of Building Performance – Expect Fire

Entry Img

The Predictability of Building Performance must take into consideration that in the context of today’s fire ground, buildings and fire dynamics, small changes on initial compartment or structure conditions may often produce and result in large-scale or magnitude changes that affect the long term outcome of the incident. We have assumed that the routiness or […]

Ready, Set, Go…

Entry Img

Before Making Entry, while in the street; Has someone completed or assigned the reconn for a 360 of the building? Have you looked at the Building and its Profile and Understood what you’re looking at? Made a Rapid Risk Assessment? Assessed the Building’s Anatomy? Considered the Compartment? Considered the Fire Dynamics? Assessed the Predictability of […]

A View from the Street

Entry Img

The Art and Science of Firefighting is aligning in a manner that will ultimately forge enhancements in…

FDNY: The 1978 Waldbaum Fire and Collapse-Remembrance 35 Years

Entry Img

The Thirty-five year anniversary of the FDNY Waldbaum’s Fire and Collapse: Do you know the lessons learned?

Large Warehouse Fire: Gastonia, NC

Entry Img

A large warehouse fire in a 211,000 SF complex resulted from a transformer explosion this morning at the Wix Distribution Center in Gastonia, NC. The building complex was a former textile mill and was built in 1917. Published report indicate that more than 60 firefighters operated at the scene to control the fire. It was […]

Three Alarm High rise Fire: FDNY Bronx

Entry Img

A three-alarm blaze tore through a South Bronx building on Saturday morning

Identifying, Establishing and Managing Collapse Zones

Entry Img

Identifying, Establishing and Managing Collapse Zones I mentioned in a recent post about on-going research and recommendations being developed for a significant report. A notable issue that seems to resonate and surface on a reoccurring bais is the identification, establishment and management of collapse zones. Building type, construction systems and materials, initiating, apparent or contributIng […]

Smart and Intelligent Firefighting

Entry Img

It’s not about NOT fighting fires, but rather fighting fires smarter.

Worcester FF Brian Carroll recalls the Arlington Street Fire of December 8, 2011

December LODD Remembrance: Worcester Fire Department with the Dec. 3, 1999, deaths of six firefighters at the Worcester Cold Storage and Warehouse Co. and the death of Firefighter Jon D. Davies Sr. on Dec. 8, 2011, during a blaze at 49 Arlington St.